Menu
Grafana Cloud

Performance considerations and limitations

Grafana Alerting supports multi-dimensional alerting, where one alert rule can generate many alerts. For example, you can configure an alert rule to fire an alert every time the CPU of individual virtual machines max out. This topic discusses performance considerations resulting from multi-dimensional alerting.

Evaluating alerting rules consumes RAM and CPU to compute the output of an alerting query, and network resources to send alert notifications and write the results to the Grafana SQL database. The configuration of individual alert rules affects the resource consumption and, therefore, the maximum number of rules a given configuration can support.

The following section provides a list of alerting performance considerations.

  • Frequency of rule evaluation consideration. The “Evaluate Every” property of an alert rule controls the frequency of rule evaluation. It is recommended to use the lowest acceptable evaluation frequency to support more concurrent rules.
  • Cardinality of the rule’s result set. For example, suppose you are monitoring API response errors for every API path, on every virtual machine in your fleet. This set has a cardinality of n number of paths multiplied by v number of VMs. You can reduce the cardinality of a result set - perhaps by monitoring errors-per-VM instead of for each path per VM.
  • Complexity of the alerting query consideration. Queries that data sources can process and respond to quickly consume fewer resources. Although this consideration is less important than the other considerations listed above, if you have reduced those as much as possible, looking at individual query performance could make a difference.

Each evaluation of an alert rule generates a set of alert instances; one for each member of the result set. The state of all the instances is written to the alert_instance table in the Grafana SQL database. This number of write-heavy operations can cause issues when using SQLite.

Grafana Alerting exposes a metric, grafana_alerting_rule_evaluations_total that counts the number of alert rule evaluations. To get a feel for the influence of rule evaluations on your Grafana instance, you can observe the rate of evaluations and compare it with resource consumption. In a Prometheus-compatible database, you can use the query rate(grafana_alerting_rule_evaluations_total[5m]) to compute the rate over 5 minute windows of time. It’s important to remember that this isn’t the full picture of rule evaluation. For example, the load is unevenly distributed if you have some rules that evaluate every 10 seconds, and others every 30 minutes.

These factors all affect the load on the Grafana instance, but you should also be aware of the performance impact that evaluating these rules has on your data sources. Alerting queries are often the vast majority of queries handled by monitoring databases, so the same load factors that affect the Grafana instance affect them as well.

Limited rule sources support

Grafana Alerting can retrieve alerting and recording rules stored in most available Prometheus, Loki, Mimir, and Alertmanager compatible data sources.

It does not support reading or writing alerting rules from any other data sources but the ones previously mentioned at this time.

Prometheus version support

The latest two minor versions of both Prometheus and Alertmanager are supported. We cannot guarantee that older versions work.

As an example, if the current Prometheus version is 2.31.1, >= 2.29.0 is supported.

The Grafana Alertmanager can only receive Grafana managed alerts

Grafana cannot be used to receive external alerts. You can only send alerts to the Grafana Alertmanager using Grafana managed alerts.

You have the option to send Grafana-managed alerts to an external Alertmanager, you can find this option in the Admin tab on the Alerting page.

For more information, refer to this GitHub issue.

High load on database caused by a high number of alert instances

If you have a high number of alert instances, it can happen that the load on the database gets very high, as each state transition of an alert instance is saved in the database.

This can be prevented by writing to the database periodically. For this the feature flag alertingSaveStatePeriodic needs to be enabled. By default, it saves the states every 5 minutes to the database and on each shutdown. The periodic interval can also be configured using the state_periodic_save_interval configuration flag.

The time it takes to write to the database periodically can be monitored using the state_full_sync_duration_seconds metric that is exposed by Grafana.

If Grafana crashes or is force killed, then the database can be up to state_periodic_save_interval seconds out of date. When Grafana restarts, the UI might show incorrect state for some alerts until the alerts are re-evaluated. In some cases, alerts that were firing before the crash might fire again. If this happens, Grafana might send duplicate notifications for firing alerts.